| Charger |
Battery Charger LED does not indicate activity when the charger and battery are plugged in |
Battery Charger is defective |
Replace Battery Charger |
| Charger |
Battery Charger LED flashes RED or GREEN, or is solid GREEN when the battery is not attached to it |
Battery Charger is defective |
Replace Battery Charger |
| Charger |
Battery Charger LED flashes RED once and stops for two seconds. It repeats five times, when the battery is attached to it |
Battery is too cold |
Take Battery to warm location for 60 minutes |
| Charger |
Battery Charger LED flashes RED twice and stops for two seconds. It repeats five times, when the battery is attached to it |
Battery is too hot |
Take Battery to cool location for 60 minutes |
| Charger |
Battery Charger LED flashes RED five times and stops for two seconds. It repeats five times, when the battery is attached to it |
Battery voltage is too low |
Replace Battery |
| Charger |
Battery Charger LED flashes green when the battery is installed and shortly thereafter turns solid green. This process repeats itself. However, the battery is not fully charged when you depress the battery button |
Battery/Charger is too hot/cold |
Take Battery/Charger to warm/cool location |
| Battery |
Battery LEDs do not illuminate |
Battery is dead or defective |
Charge or replace the Battery |
| Battery (on Powerhead) |
Powerhead will NOT start, and the Battery LEDs do NOT illuminate |
Battery is dead or defective |
Charge or replace the Battery |
| Battery (on Powerhead) |
Drilling lights come on, powerhead will not start, and battery indicates 2+ LEDs |
Battery is too cold |
Take Battery to warm location for 60 minutes |
| Battery (on Powerhead) |
Drilling lights come on, powerhead runs smoothly with no load on it, but continuously runs-stops–runs when cutting ice (battery indicates 2+ LEDs) |
Battery core temperature is too cold |
Take Battery to warm location for 60 minutes |
| Battery (on Powerhead) |
Battery LED1-LED4 flashes two times, stops for 1.2 seconds and then turn off after five occurrences during operation |
Discharge high temperature |
Take Battery to cool location for 60 minutes |
| Battery (on Powerhead) |
Battery LED1-LED4 flash four times, stops for 1.2 seconds and then turn off after five occurrences during operation |
Overvoltage protection |
Contact Customer Service |
| Powerhead |
Powerhead makes a "clicking noise" from the top of the motor cover, and will not turn. Battery LEDs indicate a full charge. With Battery disconnected, transmission output can be turned by hand, in either direction |
Motor is trying to turn, but cannot due to low or incomplete voltage to the motor |
Remove motor cover and check connections. If all connections are tight, replace the controller |
| Powerhead |
Powerhead only runs in forward |
Reverse switch is faulty (Open circuit) or has become unplugged inside handlebar control, or controller is faulty |
Remove handlebar control, replace Reverse switch or re-connect wiring. (If switch and wiring is correct, replace the Controller) |
| Powerhead |
Powerhead only runs in reverse |
Reverse switch is faulty (Closed circuit) or has become unplugged inside handlebar control, or controller is faulty |
Remove handlebar control, replace Reverse switch or re-connect wiring. (If switch and wiring is correct, replace the Controller) |
| Auger Bit |
Auger spins at normal speed, but cuts slowly through the ice |
Auger Blades are dull |
Replace Auger Blades |
| Auger Bit |
Hole count has drastically and quickly reduced and cannot be increased/restored by switching batteries |
Auger Blades are dull |
Replace Auger Blades |
| Auger Bit |
Auger drills a few inches into the ice and then just spins |
Auger Blades are dull |
Replace Auger Blades |